Use el DOI o este identificador para enlazar este recurso: http://repositorioinstitucionaluacm.mx/jspui/handle/123456789/3638
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorLentz Herrera, Álvaro Eduardo-
dc.creatorPérez Coy, Yatziry Araceli-
dc.date.accessioned2026-10-22T17:26:13Z-
dc.date.available2026-10-22T17:26:13Z-
dc.date.issued2025-07-
dc.identifier.citationPérez Coy, Yatziry Araceli. «Auditoría Energética enfocada al análisis de Iluminación en el Complejo Olímpico Méxicó 68». Tesis para optar por el Título de Licenciada en Ingeniería en Sistemas Energéticos. Universidad Autónoma de la Ciudad de México. Colegio de Ciencia y Tecnología, Programa de Energía, 2025.es
dc.identifier.urihttp://repositorioinstitucionaluacm.mx/jspui/handle/123456789/3638-
dc.descriptionTesis de Licenciatura 1 recurso electrónico (115 páginas: fotografías a color, gráficas en blanco y negro) Tesis para obtener el Título de Licenciada en Ingeniería en Sistemas Energéticoses
dc.description.abstractResumen Este trabajo describe las actividades realizadas y los resultados obtenidos durante la Auditoría Energética al Complejo Olímpico México 68, con el objetivo de identificar variables que serán analizadas y dar propuestas de mejora. Dicha auditoría fue efectuada los días 2 y 3 de octubre de 2023 por alumnos de la Universidad Autónoma de la Ciudad de México, bajo supervisión de 2 profesores de la misma institución. Se llevó a cabo una evaluación de la eficiencia energética en todas las áreas del complejo, tanto en sus edificaciones como en sus espacios exteriores, con el propósito de recopilar información sobre: a) En torno al sistema de iluminación, se realizaron mediciones de niveles de iluminación y mediciones de niveles de reflexión. b) Se realizó un censo de carga de todo el complejo, donde se contabilizaron todos los dispositivos de consumo de electricidad. Al realizar la evaluación, se encontraron zonas que no cumplieron con los niveles mínimos de iluminación establecidos en la NOM 025 STPS 2008 (STPS, 2008), “Condiciones de iluminación en los centros de trabajo”, lo cual será detallado en el documento. Dado el análisis de la auditoría energética en el complejo se identificaron deficiencias en los sistemas de iluminación, con un incumplimiento significativo de la norma NOM-025-STPS-2008. Se propone la actualización a iluminación LED donde se calcula que la recuperación de la inversión sea en 14 años, ahorrando un consumo del 40% kwh al año y la instalación de un sistema fotovoltaico de 405 paneles para reducir el consumo energético, lo que cubriría parte de la demanda de iluminación y bombas de calor, con una recuperación de inversión estimada en 6 años. Estas mejoras reducirían costos operativos y la huella de carbono. Summary This work depicts the results obtained during the energy Audit Complejo Olimpico México´68, with the objective of identifying variables that Will be analyzed and proposals for improvement. This audit was carried out on past days 2 and 3, 2023 by students of the Universidad Autónoma de la Ciudad de México, under the supervision of two teacher´s from the same institution. An evaluation of energy efficiency was conducted in all areas of the complex, both in its buildings and in its outdoor spaces, to collect information about: a) Around the lighting System, measurements of illumination levels and measurements of reflection levels were carried out. b) A load census of the entire complex was conducted, where all electricity consumption devices were accounted for. When carrying out the evaluation, areas were found that did not comply with the minimum lighting levels established in the NOM-025-STPS-2008, “Lighting conditions in work centers”, which Will be detailed in the document. Given the analysis of the energy audit in the complex, deficiencies in the lighting systems were identified, with a significant non-compliance with the NOM-025-STPS-2008 standard. The upgrade to LED lighting is proposed where the recovery of the investment is estimated to be in 14 years, saving consumption of 40% kwh per year and the installation of a photovoltaic system of 405 panels is proposed to reduce energy consumption, which would cover part of the demand for lighting and heat pumps, with an estimated investment recovery in 6 years. These improvements would reduce operating costs and carbon footprint.es
dc.language.isoeses
dc.publisherUniversidad Autónoma de la Ciudad de México. Colegio de Ciencia y Tecnología, Programa de Energíaes
dc.subjectAuditoría energética y eficiencia energética — Instalaciones deportivases
dc.subjectComplejo Olímpico México 68 — Diagnóstico energéticoes
dc.subjectAlumbrado e iluminación industrial — Normas — México (NOM-025-STPS-2008)es
dc.subjectSistemas fotovoltaicos y energía solares
dc.subjectConservación de la energía y reducción de huella de carbonoes
dc.subjectEvaluación del consumo eléctrico y censos de cargaes
dc.subjectUniversidad Autónoma de la Ciudad de México — Proyectos de ingenieríaes
dc.subjectMantenimiento y gestión de infraestructura deportivaes
dc.subjectTecnología LED y ahorro de energíaes
dc.subjectSostenibilidad ambiental en espacios públicoses
dc.titleAuditoría Energética enfocada al análisis de Iluminación en el Complejo Olímpico México ́68es
dc.typeThesises
Aparece en las colecciones: Tesis Licenciatura

Texto completo:
Archivo Descripción Tamaño Formato  
Yatziry Perez Coy Julio de 2025.pdfTesis de Licenciatura4.71 MBAdobe PDFVisualizar/Abrir


Los recursos del repositorio están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.